175 MCRM-S card replacement procedures
NT3X09
in an MCRM-S RMM
At the MAP terminal
13
14
15
16
17
18
19
20
555-4031-547 Standard 12.02 July 2002
(continued)
Test the RMM by typing the following string:
>TST
and pressing the Enter key.
Use the following information to determine where to proceed.
If TST passed
passed
failed
Return the RMM to service by typing the following string:
>RTS
and pressing the Enter key.
Use the following information to determine where to proceed.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to Step 21.
Return to the alarm clearing procedure or other procedure you
were following that directed you to this procedure. If necessary,
go to the point where a faulty card list was produced, identify the
next faulty card on the list, and go to the appropriate card
replacement procedure for that card in this manual.
Obtain further assistance in replacing this card by contacting the
personnel responsible for a higher level of support.
Do
Step 15
Step 19
Do
Step 17
Step 20