Nortel Meridian SL-100 SE Replacement page 146

Commercial systems card replacement procedures
Table of Contents

Advertisement

At the MAP terminal
19
> loadpm
20
21
22
23
Meridian SL-100 SE Commercial Systems Card Replacement Procedures MSL15
MCRM-S card replacement procedures 146
Reload the RMM by entering the following string:
and pressing the Enter key.
Use the following information to determine where to proceed.
If
message "loadfile not found in
directory" is received
load passes
load fails
Use the following information to determine where to proceed.
If you are using
Disk Drive Version 1
Disk Drive Version 2
List the loadfile in the directory by entering the following string:
>DSKUT;LISTVOL D000volume_name All
or
>DSKUT;LISTVOL D010volume_name all
and pressing the Enter key.
where
volume_name
is the name of the disk volume
Local operating company policy determines on which disk, D000
or D010, the loadfile is to be placed.Proceed to Step 24.
List the loadfile in the directory by entering the following string:
>DISKUT;LV S00D
and pressing the Enter key.
>LF S00Dvolume_name
and pressing the Enter key.
in an MCRM-S RMM
Do
Step 21
Step 25
Step 32
Do
Step 22
Step 23
NT2X09
(continued)

Advertisement

Table of Contents
loading

Table of Contents