171 MCRM-S card replacement procedures
NT3X09
in an MCRM-S RMM
2
At the MAP terminal
3
4
555-4031-547 Standard 12.02 July 2002
(continued)
the procedure for verifying or accepting cards, or have been
directed to this procedure by your maintenance support group.
Obtain a replacement card. Ensure that the replacement card
has the same product engineering code (PEC), including suffix,
as the card to be removed.
Set the MAP terminal to the peripheral module (PM) level and
post the RMM by typing the following string:
> MAPCI;MTC;PM;POST RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM from which the card is to be
removed
Example of a MAP response
CM
MS
IOD
.
.
.
SysB
RMM
PM
0 Quit
RMM
2 Post_
3
RMM 5 INSV
4
5 Trnsl
6 Tst
7 Bsy
8 Rts
9 Offl
10 LoadPM
11 Disp_
12 Next
13
14 QueryPM
15
16
17
18
Busy the RMM by typing the following string:
>BSY
and pressing the Enter key.