Nortel Meridian SL-100 SE Replacement page 85

Commercial systems card replacement procedures
Table of Contents

Advertisement

85 IPE card replacement procedures
NT8D37
in an IPE module
5
6
7
8
9
10
11
12
13
14
15
555-4031-547 Standard 12.02 July 2002
(continued)
Turn off power to the module power supply by setting the switch
on the Peripheral Equipment Power Supply (PEPS) and the
ringing generator to OFF (down).
Remove cards from the module as follows:
Tag and disconnect cables to all faceplate connectors.
Tag cards so that they can be returned to the same slot.
Remove the cards.
Place cards in a spare card cage or a shipping box for
protection.
Disconnect cables, plugs, and wires from the rear of the module
to the backplane as follows:
Remove the backplane cover by turning the screws on each
side.
Set the cover aside.
Tag and disconnect all cables from the backplane to the
interior of the I/O assembly.
Remove the power plug cover by turning the screws on each
side.
Set the cover aside.
Tag and disconnect all plugs, wires, and cables to the
backplane.
Remove the two mounting screws that secure the rear of the
card cage to the module.
Remove the module side panels from both sides of the
cardcage.
Remove the three mounting screws that secure the front of the
card cage to the bottom of the module.
Pull the card cage out of the module.
Obtain a replacement card cage.
Slide the replacement card cage into position in the module, and
install the mounting screws at the front of the card cage.
Replace the module side panels on both sides of the card cage.
Install the mounting screws at the rear of the card cage.