and washers if your rack requires them) to attach the blade to the rack. Tighten the screws. See
Figure 25 on page
83.
Figure 25: Slide Mounting Blades into Mounting Rail
9. Ensure that the PTX10001-36MR chassis is level by verifying that all the screws on the front of the
rack are aligned with the screws at the back of the rack.
Mount the PTX10001-36MR on Two Posts in a Rack
• ESD grounding strap (not provided).
• A pair of mounting rails.
• Screws to secure the mounting bracket to the chassis (12 screws are provided wit the 2-post rack
mounting kit).
• Four screws to secure the chassis and mounting bracket to the rack (not provided).
• Screwdriver appropriate for the rack-mounting screws (not provided).
• Two power cords with plugs appropriate to your geographical location (provided).
• RJ-45 cable and RJ-45 to DB-9 serial port adapter (provided).
• Management host, such as a PC laptop, with a serial port (not provided).
You can mount the PTX10001-36MR on two posts of a 19-in. rack (either a two-post or a four-post
rack) by using a two-post rack-mounting kit (must be ordered separately).
To mount the PTX10001-36MR on two posts in a rack by using the two-post mounting kit that you
purchased separately:
1. Wrap and fasten the ESD grounding strap to your bare wrist and an connect the other end of the
strap to the ESD point on the device.
83