6. Initially configure Junos OS Evolved following the instructions in
Configuration for the PTX10001-36MR" on page

PTX10001-36MR Installation Safety Guidelines

IN THIS SECTION
General Installation Safety Guidelines | 77
PTX10001-36MR Chassis Lifting Guidelines | 77
Observe the following guidelines before and during PTX10001-36MR installation:
General Installation Safety Guidelines
Before installing or moving the PTX10001-36MR, verify that the intended site meets the specified
power, environmental, and clearance requirements. See the following documentation:
"PTX10001-36MR Site Preparation Checklist" on page 47
"PTX10001-36MR Clearance Requirements for Airflow and Hardware Maintenance" on page 52
"PTX10001-36MR Rack Requirements" on page 54
"PTX10001-36MR Cabinet Requirements" on page 56
"PTX10001-36MR Environmental Requirements and Specifications" on page 49
Table 12 on page 30
or
PTX10001-36MR Chassis Lifting Guidelines
The weight of a fully loaded PTX10001-36MR is approximately 39.7 lb (18.0 kg). Observe the following
guidelines for lifting and moving a PTX10001-36MR:
CAUTION: If you are installing the PTX10001-36MR above 60 in. (152.4 cm) from the
floor, remove the power supplies and fan modules before attempting to install the
device, or ask someone to assist you during the installation.
98.
Table 18 on page 41
"Perform the Initial Software
77