Table 35: PTX10001-36MR System Alarm Messages
Component
Alarm Type
Minor (yellow)
Temperature
Major (red)
sensors
(Continued)
CLI Message
pem-number is not powered
PEM
PEM
pem-number is not supported
pem-number Not OK
PEM
PEM
pem-number Absent
pem-number Power Supply Type
PEM
Mismatch
pem-number Removed
PEM
sensor-location Temp Sensor Fail
Recommended Action
Check the power cord connection
and reconnect, if necessary.
Replace the power supply with a
supported power supply.
Indicates a problem with the
incoming AC power or outgoing DC
power. Report the error to customer
support.
A power supply is not installed.
Install a supported power supply in
the appropriate slot.
Check if there is a mix of AC and
DC power supplies in the same
chassis. Reboot the device with only
AC or only DC power supplies.
Replace the removed power supply.
Check the system log for the
following message and report it to
customer support:
sensor-number failed
Temp sensor
sensor-number ranges from
where
1 through 10.