Table 35: PTX10001-36MR System Alarm Messages
Component
Alarm Type
Minor (yellow)
Power supplies
Major (red)
(Continued)
CLI Message
Fan I2C Failure
fan-number Not Spinning
Fan
Fan/Blower Absent
pem-number Airflow not matching
PEM
Chassis Airflow
pem-number I2C Failure
PEM
Recommended Action
Check the system log for one of the
following messages and report the
error message to customer support:
• CM ENV Monitor: Get fan speed
failed
.
fan-number is NOT spinning @
fan-number
correct speed
, where
can be 0, 1, 2, 3, 4, or 5.
Remove and check the fan module
for obstructions, and then reinsert
the fan module. If the problem
persists, replace the fan module.
Check the system log for the
fan-number Absent
message
, where
fan-number
can be 0, 1, 2, 3, 4, or 5.
Install the fan module.
Replace the power supply with a
power supply that supports the
same airflow direction as the
chassis.
Check the system log for one of the
following messages and report the
error message to customer support:
• I2C Read failed for device
number
number
, where
can be from
123 throgh 125.
number : Transitioning from
• PS
online to offline
, where power
number
supply (PS)
can be 0 or 1.