Maintain The Ptx10001-36Mr Power Supplies; Remove The Ac/Hvdc Power Supply From The Ptx10001-36Mr - Juniper PTX10001-36MR Hardware Manual

Packet transport router
Hide thumbs Also See for PTX10001-36MR:
Table of Contents

Advertisement

Maintain the PTX10001-36MR Power Supplies

IN THIS SECTION

Remove the AC/HVDC Power Supply from the PTX10001-36MR | 108

Install the AC/HVDC Power Supply in the PTX10001-36MR | 110
Remove the DC Power Supply from the PTX10001-36MR | 111
Install the DC Power Supply in the PTX10001-36MR | 113
The power supplies in a PTX10001-36MR are hot-removable and hot-insertable field-replaceable units;
You can remove and replace them without powering off the PTX10001-36MR or disrupting routing
functions.
CAUTION: Do not mix AC/HVDC and DC power supplies in the same chassis.
Here are the parts and tools you'll need to replace a power supply:
• ESD grounding strap (provided)
• Antistatic bag or an antistatic mat (not provided)
• (For a DC power supply) Phillips (+) screwdriver, number 2 (not provided)
Remove the AC/HVDC Power Supply from the PTX10001-36MR
WARNING: Turn off the power source before disconnecting the power cord to prevent
damage to the power connector contact.
WARNING: If you need to replace all the power supplies installed in your
PTX10001-36MR, you must power off the PTX10001-36MR before removing the
power supplies. See
"Power Off the PTX10001-36MR" on page
100.