Juniper PTX10001-36MR Hardware Manual page 141

Packet transport router
Hide thumbs Also See for PTX10001-36MR:
Table of Contents

Advertisement

Table 35: PTX10001-36MR System Alarm Messages
Component
Alarm Type
Minor (yellow)
Routing Engine
Major (red)
Minor (yellow)
(Continued)
CLI Message
sensor-location Temp Sensor Too Hot
sensor-location Temp Sensor Too
Warm
RE number /var partition is full
RE
RE number /var partition usage
RE
is high
Recommended Action
Check environmental conditions
and alarms on other devices. Ensure
that environmental factors (such as
hot air blowing around the
equipment) do not affect the
temperature sensor. If the condition
persists, the device might shut
down.
For information only. Check
environmental conditions and
alarms on other devices. Ensure that
environmental factors (such as hot
air blowing around the equipment)
do not affect the temperature
sensor.
Clean up the system file storage
space on the device. For more
information, see
request system
storage cleanup
.
Clean up the system file storage
space on the device. For more
request system
information, see
storage cleanup
.