EAW UMX.96 Owner's Manual
12.5.1.17 Output Limiter
The output limiter can actually function as a compressor or as a limiter, dependent on its ratio setting.
Compressor Controls
Limiter IN
Threshold
Attack
Release
Ratio
Input Meter
Reduction Meter
Output Meter
12.5.1.18 Mute
The MUTE button mutes the signal for that output leg.
12.5.1.19 Output Meter
The OUTPUT meter displays the signal level for that output leg. The meter is calibrated in dB relative to digi-
tal full scale (dBFS). 0 dB corresponds to +22 dBu (output clipping level).
In/Out
GR Threshold
Attack time
Release time
Compression ratio
Input level
Gain reduction applied
Output level
12-61
0 to –60 dBFS
0.1 ms to 300 ms
50 ms to 3 seconds
1:1 to infinity:1
–48 dBFS to 0 dBFS
–30 dB to 0 dB
–48 dBFS to 0 dBFS