Data can be manually copied from one column to the other by using the following two softkeys:
SET>ACTV (Set to Active)—allows the installer to send the information in the SET column (data stored
in the master configuration module) to the ACTV column (data used by the LRU).
ACTV>SET (Active to Set)—causes the current settings of the LRU to be copied to the master
configuration module as SET items.
4.6
CONFIGURATION STATUS
Whenever configuration settings are changed, the technician receives on-screen prompts and/or
confirmation similar to those shown in Figure 4-5.
4.7
DATA TRANSMISSION INDICATORS
Several configuration pages use an indicator light system to show discrete (ON/OFF) data and/or
hardware component status. Unless otherwise noted, the following applies to all configuration page
status indicators:
Green―expected data is successfully received and is ON. A green light can also indicate that the
•
parameter/component is working correctly.
Red―expected data is not received. A red light can also indicate that a parameter/component is
•
invalid.
Black―expected data is successfully received and is OFF, or no data is expected. A black light can
•
also indicate that the parameter/component is not responding.
A blank ACTIVE column displays the loss of communication between the display and a specific LRU
(Figure 4-7).
Page 4-6
Rev. B
Figure 4-5. Configuration Status Prompts
Figure 4-6. Data Transmission Indicators
Figure 4-7. Loss of Communication Indication
G1000 System Maintenance Manual
190-00907-00