System Annunciation Troubleshooting (continued)
Annunciation
Engine/Airframe Sensors
Page 5-8
Rev. B
Associated
LRU
Check PFD Alert Window for GIA1/2 or GEA
configuration, software or failed data path error
messages. Correct any errors before proceeding.
On the PFD in Configuration Mode, turn to the GE
STATUS page and verify that the GEA internal
power supply, configuration, and calibration status
boxes are green.
If the internal power supply box is red, check for
shorted engine/airframe sensors that receive
5V, 10V or 12V power from the GEA (tach
sensor, MAP sensor, Fuel Flow sensor, oil
pressure sensor and pitot heat sensor).
The configuration and calibration boxes should
be green. If the calibration status boxes are
red, replace the GEA 71.
GEA 71 &
Verify the internal, external, and reference voltages
GIA 63 or
listed in the Main Analog and I/O A Analog boxes
GIA63W
are not dashed out (does not include Aircraft Power
1 and 2). If any voltages are dashed out, replace the
GEA.
Check the MFD AUX – SYSTEM STATUS page if
the GEA is online (green checkmark on the AUX –
SYSTEM STATUS page is present). If GEA is not
online (Red-X is present), verify the unit is receiving
power at the GEA rack connector.
Replace the GEA 71.
If problem persists, check the GIA/GEA interconnect
wiring and unit connector pins for faults.
For only REX-X of the EGT, TIT and CHT
temperature readings, replace the GEA
configuration module and thermocouple located in
the back shell of the GEA connector.
Solution
G1000 System Maintenance Manual
190-00907-00