7.8

GTX SOFTWARE INSTALLATION AND TESTING

Original GTX Reinstalled:
No software or configuration loading is required if the original GTX is reinstalled. This does not
include units that were returned for repair as their software and configuration files are deleted
during the repair testing process.
New, Repaired or Exchange GTX is Installed:
Ensure that the correct airframe type is selected before proceeding; otherwise,
incorrect configuration information will be loaded.
If a new, repaired or exchange GTX is installed; load the following files after removing the
Supplemental Database cards from the bottom slots of each display. Note which card was
removed from the MFD so it may be identified later for reinsertion in the MFD when software
and configuration loading is complete. It contains a FliteChart® or ChartView database which is
only used in the MFD. Reinstall all the cards after the software and configuration file loads are
complete.
GTX1 Software
GTX2 Software
GTX1 Configuration
GTX2 Configuration
After loading software and configuration files, turn to the transponder configuration page and
enter the registration (address) and flight ID numbers.
7.8.1 GTX Testing
If unit is removed or replaced the following tests are recommended:
The integrated transponder/altitude reporting system must be verified in accordance with Title
14 of the Code of Federal Regulations (CFR) §§ 91.411 and 91.413.
Transponder Ramp Test
This test requires the use of a Mode S ramp generator. Specific instructions for operating the
ramp tester are contained in the applicable operator's manual. Refer to Title 14 CFR Part 43
Appendix F for testing criteria.
7.9

GDL SOFTWARE INSTALLATION AND TESTING

Original GDL Reinstalled:
No software or configuration loading is required if the original GDL is reinstalled. This does not
include units that were returned for repair as their software and configuration files are deleted
during the repair testing process.
New, Repaired or Exchange GDL is Installed:
If a new, repaired or exchange GDL is installed; load the following files after removing the
Supplemental Database cards from the bottom slots of each display. Note which card was
removed from the MFD so it may be identified later for reinsertion in the MFD when software
and configuration loading is complete. It contains a FliteChart® or ChartView database which is
only used by the MFD. Reinstall all the cards after the software and configuration file loads are
complete.
G1000 System Maintenance Manual
190-00907-00
NOTE
Page 7-31
Rev. B