GIA1 ARINC 429
Channel
LRU
GDC 74A
IN 5
#1
Page 5-18
Rev. B
Indicator
GIA1/GDC 74A data path is functioning correctly.
GIA1/GDC 74A data path is not functioning correctly.
•
Check PFD Alert Window for GIA or GDC configuration
or software error messages. Correct any errors before
proceeding.
•
Verify GDC 74A status is OK using the AUX –
SYSTEM STATUS page on the MFD. If it has a Red-
X, troubleshoot why the GDC is offline before
proceeding.
•
Swap GIA1 and GIA2, reconfigure both GIA's to their
new locations to confirm if the problem is in the original
GIA1.
−
Replace original GIA1 if box turns green after
swapping units.
•
Check the GIA1/GDC 74A interconnect wiring and unit
connector pins for faults.
•
Replace GDC 74A
GIA1/GDC 74A data path functionality is unknown.
Reload GIA1 configuration files.
Status
G1000 System Maintenance Manual
190-00907-00