4.5

'SET' AND 'ACTIVE' COMMANDS

The SET and ACTIVE commands on various configuration pages are used for setting input/output
conditions (Figure 4-4).
SET Column
SET>ACTV and ACTV> Softkeys
4.5.1 SET and ACTIVE Softkeys
Use the ACTV>SET softkey with care. If an improperly configured unit is installed,
this softkey causes the wrong configuration to replace the correct one.
When troubleshooting the system, the technician can look for inequalities (configuration mismatches)
between the SET and ACTIVE columns. Certain problems can be resolved by pressing the SET>ACTV
softkey which reloads settings to the specific LRU from the PFD (this can also be accomplished by
reloading the configuration files for the LRU using the G1000 SW Loader Card).
Definitions
SET—refers to a setting or group of settings that reside in the PFDs internal memory and/or master
configuration module.
ACTIVE—refers to a current setting stored and used in a LRU. LRUs store the 'active' settings within
internal memory.
G1000 System Maintenance Manual
190-00907-00
ACTIVE Column
Figure 4-4. SET and ACTIVE Softkeys and Columns
NOTE
Page 4-5