6.5

GRS REPLACEMENT

To remove:
1. Disconnect Backshell connector from unit.
2. Loosen four screws holding the unit to the mounting rack (do not loosen mounting rack bolts).
To install:
1. Inspect connector(s) for damaged pins.
2. Fasten unit to mounting rack.
3. Connect Backshell assembly to unit.
6.6

GMU REPLACEMENT

To remove:
1. Loosen three screws connecting the unit to the aircraft mounting plate.
2. Disconnect cable.
To install:
1. Inspect connector for damaged pins.
2. Connect cable and properly secure connector in a stationary fashion.
3. Fasten unit to the aircraft mounting rack.
6.7

GDC REPLACEMENT

To remove:
1. Loosen two thumb screws that secure the unit to the mounting rack
2. Disconnect Backshell assembly and pitot-static plumbing from unit.
3. Remove all Teflon tape or sealing compound. Take care not to allow Teflon tape or sealing
compound to fall inside unit.
To install:
1. Inspect connector(s) and pitot-static plumbing for damage.
2. Install Teflon tape or sealing compound to pitot-static plumbing
3. Connect Backshell assembly and pitot-static plumbing to the unit.
4. Tighten two thumb screws that secure the unit to the mounting rack.
6.8

GEA REPLACEMENT

To remove:
1. Loosen the Phillips screw to unlock unit handle.
2. Pull the GEA lever up towards the top of the unit. This disengages the locking stud with the dogleg
slot.