5.4.3 Cooling Alerts
Message
MFD1 COOLING – has poor
cooling. Reducing power
usage.
PFD1 COOLING – has poor
cooling. Reducing power
usage.
5.4.4 Key Alerts
Message
MFD1 "key" KEYSTK – key is
stuck.
PFD1 "key" KEYSTK – key is
stuck.
Page 5-34
Rev. B
Cause
The MFD has exceeded
its operating temperature
range.
PFD1 has exceeded its
operating temperature
range.
Cause
The system has
determined a key is stuck
on the MFD.
The system has
determined a key is stuck
on PFD1.
Solutions
Check cooling fan and wiring for
proper operation.
Replace cooling fan if unable to
determine if operating correctly.
If problem persists, replace the
MFD.
Check cooling fan and wiring for
proper operation.
Replace cooling fan if unable to
determine if operating correctly.
If problem persists, replace the PFD.
Solutions
Go to the GDU TEST page in
configuration mode and verify key is
stuck (if key is stuck the
corresponding indicator will be
green).
Exercise suspected stuck key and
reset GDU TEST page to see if
indicator remains green without
pressing the key.
If problem persists replace the
display.