_______________________________________________________________________
To install:
1. Inspect the output gear for abnormal wear or the absence of grease.
2. Carefully place the servo into the capstan, ensuring proper orientation and alignment.
3. Fasten the servo to the capstan using the existing hardware.
4. Inspect the Backshell assembly and connector for damaged pins.
5. Connect Backshell assembly to the unit.
6.13 GSM REPLACEMENT
To remove:
1. Remove the GSA Servo.
2. De-rig the flight control cabling or chain.
3. Use a socket or open-wrench to loosen and remove the servo attachment bolts.
4. Carefully remove the servo mount.
To install:
Follow the installation instructions in the respective servo installation drawing. If no other maintenance is
to be performed, reinstall the servo(s).
G1000 System Maintenance Manual
Page 6-5
190-00907-00