GIA2 ARINC 429 (continued)
Channel
LRU
IN 6
GRS 77 #1
Page 5-24
Rev. B
Indicator
GIA2/GRS 77 data path is functioning correctly.
GIA2/GRS 77 data path is not functioning correctly.
•
Check PFD Alert Window for GIA or GRS configuration
or software error messages. Correct any errors before
proceeding.
•
Verify GRS77 status is OK using the AUX - SYSTEM
STATUS PAGE on the MFD. If it has a Red-X,
troubleshoot why the GRS is offline before proceeding.
•
Ensure GRS77 #1 connecter is secure and proper wire
harness strain relief is provided.
•
Swap GIA1 and GIA2, reconfigure both GIA's to their
new locations to confirm if the problem is in the original
GIA5.
−
Replace original GIA2 if box turns green after
swapping units.
•
Check the GIA2/GRS 77 interconnect wiring and unit
connector pins for faults.
•
Replace GRS 77.
GIA2/GRS 77 data path functionality is unknown. Reload
GIA2 configuration files.
Status
G1000 System Maintenance Manual
190-00907-00