Gtx 33 Related Alerts And Problems - Garmin G1000 Maintenance Manual

Hide thumbs Also See for G1000:
Table of Contents

Advertisement

__________________________________________________________________

5.11 GTX 33 RELATED ALERTS AND PROBLEMS

Message
XPDR1 CONFIG – XPDR1
configuration error. Config
service req'd.
MANIFEST – GTX1 software
mismatch. Communication
Halted.
XPDR1 SRVC – XPDR1
needs service. Return unit for
repair.
XPDR1 FAIL – XPDR1 is
inoperative.
G1000 System Maintenance Manual
190-00907-00
Cause
The system has detected
a GTX33 configuration
mismatch.
The system has detected
an incorrect software
version loaded in GTX 33.
The system has detected
a failure in GTX 33.
GTX 33 is not responding.
Solutions
Perform a SET>ACTV configuration
reset on the GTX Config page.
For a GTX33, verify the aircraft
registration is present in the GTX
Configuration page.
If error is still present, reload config
files from a loader card. See
Section 7.
If problem persists, replace master
configuration module, check config
module harness for faults and
replace if necessary.
NOTE
New Terrain/Obstacle cards,
Jeppesen Aviation Database and
other optional features (i.e. TAWS
card) will need to be replaced if the
master configuration module is
changed. The System ID number
will change to a new number when
installing a new master config
module. The old Terrain and other
cards will no longer work as they will
remain locked to the old System ID
number.
Load correct software version
Replace GTX 33.
Check GIA1/2 to GTX33 data paths
for failures per Section 5.3.
Replace GTX 33.
Page 5-63
Rev. B

Advertisement