Garmin G1000 Maintenance Manual page 39

Hide thumbs Also See for G1000:
Table of Contents

Advertisement

__________________________________________________________________
5.1.2
System Annunciation Troubleshooting
Annunciation
NAV1 or COM1
NAV2 or COM2
G1000 System Maintenance Manual
190-00907-00
Associated
LRU
Check PFD Alert Window for GIA1 configuration,
software or failed data path error messages.
Correct any errors before proceeding.
Swap GIA1 and GIA2 and reconfigure for their new
positions to verify location of problem:
GIA1
If problem follows GIA1, replace GIA1.
Check Ethernet interconnect from GIA1 to PFD and
unit connector pins for faults.
If problem persists, replace PFD.
Check PFD Alert Window for GIA2 configuration,
software or failed data path error messages.
Correct any errors before proceeding.
Swap GIA1 and GIA2 and reconfigure for their new
positions to verify location of problem:
GIA2
If problem follows GIA2, replace GIA2.
Check Ethernet interconnect from GIA2 to MFD and
unit connector pins for faults.
If problem persists, replace MFD.
Solution
Page 5-3
Rev. B

Advertisement