Garmin G1000 Maintenance Manual page 152

Hide thumbs Also See for G1000:
Table of Contents

Advertisement

_________________________________________________________________
Table 7-2. Magnetometer Interference Test Sequence (example)
Test (min:secs)
When the CALIBRATE field is blinking, press the ENT key to begin the procedure, and have a
stopwatch ready to begin recording the elapsed time.
Page 7-26
Rev. B
Elapsed Time
since Start of
0:00
Test begins
0:10
Aileron full right
0:20
Aileron full left
0:30
Aileron level
0:40
Flaps down
0:50
Flaps up
1:00
Landing gear up
1:20
Landing gear down
1:40
Speed brake up
1:50
Speed brake down
2:00
Navigation lights on
2:10
Navigation lights off
2:20
Landing lights on
2:30
Landing lights off
2:40
Taxi lights on
2:50
Taxi lights off
3:00
Landing + Taxi lights on
3:10
Landing + Taxi lights off
3:20
Strobes on
3:30
Strobes off
3:40
Recognition lights on
3:50
Recognition lights off
4:00
Turn on all wing-tip lights
simultaneously (typically
will include navigation
lights, recognition lights
and strobe)
4:10
Turn off all wing-tip lights
simultaneously
4:20
Beacon on
4:30
Beacon off
4:40
Pitot heat on
4:50
Pitot heat off
5:00
End of test
Action
G1000 System Maintenance Manual
190-00907-00

Advertisement

Table of Contents
loading

Table of Contents