AINTENANCE
There are several procedures that should be completed on an annual basis. There procedures help to insure proper opera-
tion of the system on a long term basis. Refer to Table 59 for a listing of the annual maintenance items.

Inspecting and Replacing Scraper Blades

Scraper blades should be inspected for wear during the annual maintenance check. To inspect the blades, perform the pro-
cedure in Table 61.
!
WARNING:
In Step 2, when purging is complete, disconnect electrical power from the unit. Failure to disconnect the power could result
in serious injury, death, or equipment damage. .
Step
1.
2.
3.
4.
5.
6.
Publication Number: 620073146SER
Open the merchandiser
Remove the filter, shown in Figure 63, by grasping the two tabs and sliding it straight
out the front of the unit.
Wash the filter with clean water. Shake out the excess water.
Reinstall the air filter.
Close the merchandiser.
Figure 63. Air Filter Location
"Purging a Barrel" on page 55.
disconnect electrical power
When purging is complete,
Remove the four (4) 3/4 in. nuts from the faceplate and slowly remove the faceplate
from the unit.
Slowly pull the blade assembly out of the barrel.
Rinse and inspect the blade assembly for signs of wear.
If there is significant wear on the blades, Reverse or replace them, depending on the
wear pattern.