CAUTION
service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL
CODES.
P
M
REVENTIVE
AINTENANCE

Preventive Maintenance Summary

Clean air filter (on air cooled units)
Clean condenser
Sanitize unit
Change or rotate scraper blades
Inspect Double Liquid Check Valve
Check for leaks
Check BRIX
Clean BIB connectors
Check clock setting

Cleaning Air Filter (Integral Only)

1. The air filter should be cleaned every month. Remove the filter by sliding it straight back. Wash with
mild soap solution, rinse with clean water, and shake out excess water (or blow with low pressure com-
pressed air if available).
2. Vacuum the condenser coil or blow it out with low pressure compressed air before reinstalling the air
filter.
3. Reinstall the air filter.

Sanitizing

The syrup systems should be sanitized every 6 months per the following procedure using a non-scented
liquid household bleach containing a 5.25% sodium hypochlorite concentration.
1. Press <OFF> from the BARREL STATUS menu on the Control Panels to stop beater and refrigeration
on all cylinders.
2. Take the following actions from the Control Panel:
• From the BARREL STATUS menu, press <MENU>.
• From the CHOOSE MODE menu, select <MANUAL DEFROST> and press <GO>.
• Select barrel and press <DFRST>.
© 2003-2014, Cornelius Inc.

SERVICE

— Only trained and certified electrical, plumbing and refrigeration technicians should
Preventive Maintenance Summary
Procedure
Pinnacle 2 and 4 Flavor Service Manual
- 8 -
Frequency
Monthly or as necessary
every 6 months
every 6 months
every 6 months
every 6 months
every 6 months
every 6 months
every 6 months
every 6 months
Publication Number: 560007298SER