CO
Requirements
2
!
WARNING:
CO
displaces oxygen. Persons exposed to high concentrations of CO
2
consciousness and death. It is very important to prevent CO
ventilate the area before fixing the leak.
NOTE: There are two CO
High pressure Cylinder requires a primary regulator with a minimum inlet pressure of 500 psi.
Low Pressure Bulk System requires a secondary regulator with a maximum inlet pressure of 200 psi.
NOTE: CO
connections require 3/8" I.D. tubing. All hoses must reach the back of the unit plus an adequate amount of
2
extra tubing to allow the unit to be pulled out for servicing.
NOTE: Use a dedicated secondary regulator adjusted to 75 ±1 psig to supply the unit.
CO
Connections
2
Use a source-dedicated secondary regulator, fittings and clamps to connect the CO
regulator for 75 ±1 psig at the unit. Run the tubing for the CO
connections. Ideally, locate the regulator within 3 ft. of the unit. Another secondary regulator is to be used to supply the Bag in Box
pumps. It is to be set to 75 psig, not lower. Do not turn on the CO
© 2022, Marmon Foodservice Technologies Inc.
delivery systems available: High Pressure Cylinder; Low Pressure Bulk System.
2
2
- 11 -
Viper Installation, Service & Decommissioning Manual
will experience tremors, followed by loss of
2
leaks, especially in small unventilated areas. If a CO
2
line to the unit, as shown in Figure 8. Set the
2
from the secondary regulator to the unit and make all appropriate
supply to the unit.
2
leak occurs
2
Publication Number: 620073146SER