Displayed
Action
Message
COM ERR STAT
HIGH VOLTAGE
LOW VOLTAGE
NO MOTOR
FILL ERROR
H
O OUT
2
CO
OUT
2
SYRUP OUT
CLOCK
MTR CTL
EEPROM
Button
BACK
RESET

Error Log Menu

The Error Log screen displays information about any errors generated by the unit, as shown in Figure 43. If no errors have been
detected, the right side of the display is blank. To view more than one error, press the Up or Down arrows on the right side of
the display to scroll through the error log. Button functions are described in Table 34.
Button
BACK
© 2022, Marmon Foodservice Technologies Inc.
Table 32.
Type
Limp
Communications error, the system continues to run.
The unit is experiencing voltage greater than 260VAC. System is enabled when line
System
voltage drops below 260VAC for two minutes.
The unit is experiencing voltage less than 200VAC. System is enabled when line volt-
System
age rises above 200VAC for two minutes.
The motor is reporting no current draw when activated. Motor is unplugged or ther-
Barrel
mal cutoff has tripped.
Barrel
Barrel has not filled properly within 2 min.
Water pressure is too low for proper operation. This error occurs when the H
System
sor reports no or low water pressure for more than one second. Error is cleared 10
sec. after restoral.
CO
pressure is below required operating pressure. This error occurs when the CO
2
System
sensor reports no or low CO
sec. after restoral.
Syrup pressure is below required operating pressure. This error occurs when the
Barrel
syrup sensor reports no or low syrup pressure for more than one second. Error is
cleared 10 sec. after restoral.
System
The real time system clock is not functioning.
System
Motor control EEPROM is bad or missing.
Table 33.
Returns the display to the Select menu
Allows the user to reset the highlighted error (This button only appears on
certain manually resettable errors.)
Figure 43. Error Log Screen
Returns the display to the Select menu
- 57 -
Viper Installation, Service & Decommissioning Manual
Description
pressure for more than one second. Error is cleared 10
2
Description
Description
O sen-
2
2
Publication Number: 620073146SER

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-454c