Unit Data Menu; Error Status Menu - Cornelius VIPER E 2 FLAVOR Manual

Hide thumbs Also See for VIPER E 2 FLAVOR:
Table of Contents

Advertisement

When the Select menu is displayed, the Unit Data is highlighted. To access the Unit Data menu, press the GO button. Refer to
Table 29, the Select menu, for button functions.
Button
BACK
MAIN
SETUP
MAINT
GO

Unit Data Menu

The Unit Data screen, shown in Figure 41, provides information about the individual barrels in the system. When DATA is
highlighted and the GO button is pressed on the Select menu, the display shows the first barrel in the system and some of its
parameters. To view the next barrel, press the down arrow on the right side of the display. Continue pressing the down arrow
to view the data on all barrels in the system. Refer to Table 30 for button functions.
Button
BACK
BRL
UNIT
VER

Error Status Menu

The Error Status menu, shown in Figure 42, displays any current errors contained in the Error Messages List.
There are three types of errors that can be generated by the system. These error types and a description of their meaning are
listed in Table 31.
© 2022, Marmon Foodservice Technologies Inc.
Viper Installation, Service & Decommissioning Manual
Table 29.
Returns the display to the Barrel Status menu
Highlighted to indicate current menu
Opens the Setup menu
Displays and opens Maintenance menu, if security is off or accessed
Opens the highlighted selection on the current menu
#1 FREEZE
UNIT
o
DATA
OUTLET TEMP 33
F
VISCOSITY:
9
REFRIGERATION: ON
12:51P
AV OZ/HR/3 HR:
80
MAR 04
DEFROST TIMER: 2:50:23
BACK
BRL
UNIT
VER
Figure 41. Unit Data Screen
Table 30.
Returns the display to the Select menu
Displays the data for a single barrel, including Outlet Temperature, Viscos-
ity, if Refrigeration is On or Off, Average Ounces of product dispensed per
hour for the last three hours and Defrost Lock Time until next defrost
Displays the real time input voltage and frequency being supplied to the
unit and the low, high or both refrigeration pressures for the unit,
depending on the settings of the compressor sensors in the Unit Data
screen.
Displays the version number of the UI, I/O, Motor and Status boards
installed in the unit
- 55 -
Description
Description
Publication Number: 620073146SER

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-454c

Table of Contents