Figure 29.

Filling the Barrels

Once the barrels have been BRIXed and purged, they may be filled with product. This is accomplished by going to the Barrel Maintenance
menu and pressing the FILL button. This starts the fill process for the highlighted barrel. As the barrel fills, the barrel pressure sensor
shuts off the barrel at a pressure of 28 psi. To completely fill the barrel, open the relief valve on the faceplate of the barrel and allow
some of the barrel pressure to escape. This allows the barrel to continue filling. Repeat this process until the product level is at the height
indicated in based on product type. Once the product reaches the proper level, press the OFF button to stop filling the barrel. Press the
FREEZE button to start mixing and cooling the product and the CO
present in the barrel.
2

Calibrating a Motor

Motors are factory calibrated, but storage and transit can cause a shift in calibration. Calibration establishes a new baseline for the
motor assembly. This allows the system to determine proper viscosity settings for the motor. As a part of installation, each barrel should
be calibrated using the procedure in Table 24. and Table 25.
!
CAUTION:
Calibration must be performed when the product in the barrel is completely liquid. There must not be any ice on the
scraper blade.
The Motor Setup Screen in Figure 30. allows you to select different motor types for each barrel in the unit and run the calibration
procedure on that motor. This procedure correlates the actual viscosity of the barrel and its contents with the electrical characteristics of
the motor. There are two options for Motor Type. Motor Type 1 is for 60 Hz units and motor type 2 is for 50 Hz units. The type of unit can
be verified on the unit data plate. Perform the procedure described in Table 24. to verify the motor type setting.
NOTE: If the Motor Type shown is "DEFAULT", it indicates that the EEPROM is not installed or is faulty.
Figure 30. Motor Setup Screen