Cornelius VIPER E 2 FLAVOR Manual page 105

Hide thumbs Also See for VIPER E 2 FLAVOR:
Table of Contents

Advertisement

Viper Installation, Service & Decommissioning Manual
Restricted Air Flow
Fan Motor
Hot Gas Valve
No/Low Refrigerant
Sensors
Publication Number: 620073146SER
Table 57.
A. Dirty filter.
B. Dirty condenser.
C. Damaged fins.
D. Not enough "clearance" around unit.
A. Bad connection
B. Bad motor
C. Cracked or bent fan blade
A. Miswired.
B. Defective coil.
C. Defective product delivery board.
A. Leak.
A. Bad connection.
B. Bad sensor.
C. Sensor out of position.
D. Defective product delivery board.
- 102 -
A. Clean filter.
B. Clean condenser.
C. Repair/replace if necessary.
D. Ensure proper spacing around unit.
A. Check/connect
B. Replace motor
C. Replace fan blade
A. Correct wiring.
B. Replace coil.
C. Replace.
A. Repair and weigh in new charge.
A. Correct wiring.
B. Replace sensor.
C. Reposition sensor and clip.
D. Replace.
© 2022, Marmon Foodservice Technologies Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-454c

Table of Contents