Step
1
Set barrel for Motor Type
2
Select the barrel
Select the proper motor
3
type
4
Complete the procedure
Step
1
Select Motor Setup
2
Select the barrel
3
Start calibration
4
Complete the procedure
5
Verify
© 2022, Marmon Foodservice Technologies Inc.
Viper Installation, Service & Decommissioning Manual
Table 24.
Action
From the Maintenance menu (Figure 31.), open the
Motor Setup menu, shown in Figure 30.
Use the Up and Down arrows to highlight the desired
barrel
Press the + or - buttons at the bottom of the display to
set the motor type to 1 for 60 Hz or 2 for 50 Hz
Press the BACK button at the bottom of the display to
save the settings and return to the Setup menu.
Figure 31. Select Screen
Table 25.
Action
Use the Up and Down arrows to highlight MOTOR
SETUP on the Maintenance menu.
Use the Up and Down arrows to highlight the desired
barrel
Press the CAL button at the bottom of the Motor
Setup menu to start the calibration process.
The calibration cycle continues for five (5) minutes to
allow the gearbox to stabilize at temperature and
ensure correct calibration. At that time the motor
stops and it is calibrated.
Press the BACK button at the bottom of the display to
return to the Maintenance menu.
Select SPIN to run the motor and visually ensure that
the calibration reading is 20 +/- 2.
- 35 -
Procedure
Procedure