Setting Defrost Lockout - Cornelius VIPER E 2 FLAVOR Manual

Hide thumbs Also See for VIPER E 2 FLAVOR:
Table of Contents

Advertisement

Viper Installation, Service & Decommissioning Manual
Step
Action
4
Select SLEEP
5
Set hour field
6
Set minute field
7
Select AM/PM field
8
Select DAY for Wake up
9
Select WAKEUP
When the sleep and wake up settings are complete, press the BACK button to save the settings and return to the Select menu.

Setting Defrost Lockout

From the Barrel Status menu, shown in Figure 39, press the MENU button and then press the SETUP button to display the
Setup menu. Use the up and down arrows on the right of the control to highlight the Events Setup menu, then press GO to
enter the menu.
The lockout can also be set day by day or for all days with up to three lockout periods of three hours each per day. These
lockout periods may be overlapped to provide from three to nine hours of defrost lockout, if desired. When the periods are
overlapped, it is recommended that the defrost lockouts for sequential lockout periods be overlapped by 15 minutes. The
defrost lockout affects all barrels in the unit. To set the defrost lockouts, perform the procedure in Table 42.
Step
Action
1
Set defrost lockout
2
Select DAY
3
Set DAY
4
Select DEFROST LOCK 1
5
Set hour field
6
7
Set minute field
8
9
Select AM/PM field
10
11
Select DEFROST LOCK 2
12
Select DEFROST LOCK 3
When the defrost lockout settings are complete, press the BACK button to save the settings and return to the Select menu,
shown in Figure 44.
Publication Number: 620073146SER
Table 41.
Use the up and down arrows to highlight SLEEP.
Use the left and right arrows to select the hour field and press the + or - buttons to
change the hour.
Use the left and right arrows to select the minute field and press the + or - buttons to
change the minutes (15 min. increments)
If the 12 hour clock option is selected, use the left and right arrows to select the AM/
PM field. Then press the + or - buttons to change between AM and PM.
Repeat Steps 2 and 3 as needed.
Use the up and down arrows to highlight WAKEUP and repeat Steps 5 through 7 to
set the WAKEUP times.
Table 42.
Open Events Setup menu, shown in Figure 47.
The DAY field is highlighted.
Use the + and - buttons at the bottom of the display to set the desired day or all days.
Use the up and down arrows to highlight DEFROST LOCK 1.
Use left and right arrows to select hour field
Use the + and - buttons at the bottom of the display to set the desired hour.
Use left and right arrows to select minute field
Use the + and - buttons at the bottom of the display to set the desired minute (in 15 min.
increments).
If the 12 hour clock option is selected, use the left and right arrows to select the AM/PM
field.
Use the + button at the bottom of the display to set the AM/PM field.
Repeat Steps 2 through 10 for the DEFROST LOCK 2 time, if desired.
Repeat Steps 2 through 10 for the DEFROST LOCK 3 time, if desired.
- 62 -
Procedure
Procedure
© 2022, Marmon Foodservice Technologies Inc.