Viper Installation, Service & Decommissioning Manual
if the ambient temperature is at 75°F. The times will vary depending on the ambient temperature (a higher ambient tem-
perature requires more time for the product to cool).

Viscosity Setting

The control system includes a function to select the desired product viscosity. This function is referred to as "Viscosity Set-
ting". There are selectable viscosity ranges from 1-9. The higher the number selected, the more viscous the frozen product
in the barrel becomes. This increased viscosity is achieved by freezing the product in the barrel to a lower temperature
thereby increasing ice crystal size/growth. As the ice crystal size increases, however, there is potential for product quality to
diminish.
Cornelius recommends that the viscosity settings be set at the lowest possible setting to achieve the desired drink quality.
In most typical installations using a sugar-based syrup, acceptable drink quality can be achieved by programmed viscosity
settings in the range of 3-5 for Viper.
Diet FCB syrups freeze much more readily than sugar based syrups, so the viscosity setting should be selected at the mini-
mum value available (which is 1 or 2 for the Viper).
S
U
TARTING THE
NIT
The following table, Table 11., describes the basic procedure for starting the Viper. Refer to the Operator's Manual (P/N
620073146OPS) for details on operation of the Viper unit.
Step
1.
Open the merchandiser
2.
Turn on the barrels
3.
Close the merchandiser.
Publication Number: 620073146SER
Table 58.
Action
Open the merchandiser and expose the control panel.
Turn all barrels on by pressing the buttons labeled ON to
start the normal refrigeration process.
Close the merchandiser. In approximately 20 minutes,
product is ready to serve.