Cornelius VIPER E 2 FLAVOR Manual page 29

Hide thumbs Also See for VIPER E 2 FLAVOR:
Table of Contents

Advertisement

Viper Installation, Service & Decommissioning Manual
Setting Defrost Lockout
From the Barrel Status menu, shown in Figure 17. press the MENU button and then press the SETUP button to display the Setup menu.
Use the up and down arrows on the right of the control to highlight the Events Setup menu, then press GO to enter the menu (Figure
23.).
This menu allows the user to set the unit for a sleep period on individual days or all days of the week. It also provides a lockout for the
automatic defrost cycle, so that all barrels have product available during peak usage hours. The lockout can also be set day by day or for
all days with up to three lockout periods per day. The defrost lockout affects all barrels in the unit. To set the defrost lockouts, perform
the procedure in Table 15. Defrost lockouts should be overlapped by 15 minutes for sequential lockout.
Step
1
2
3
4
5
6
7
8
9
10
When the defrost lockout settings are complete, press the BACK button to save the settings and return to the Select menu, shown in
Figure 19.
Setting the Sleep and Wake up Times
Sleep and wake up times are set on the Event Setup menu shown in Figure 23. To set the sleep and wake up times, perform the
procedure in Table 16.
Publication Number: 620073146SER
Action
Set defrost lockout
Open the Events Setup menu, shown in Figure 23.
Select DAY
Use the up and down arrows to highlight DAY.
Use the + and - buttons at the bottom of the display to set
Set DAY
the desired day or all days.
Use the up and down arrows to highlight DEFROST LOCK
Select DEFROST LOCK 1
1.
Use the left and right arrows to select the hour field.
Set hour field
Use the + and - buttons at the bottom of the display to set
the desired hour.
Use the left and right arrows to select the minute field.
Set minute field
Use the + and - buttons at the bottom of the display to set
the desired minute (in 15 min. increments).
If the 12 hour clock option is selected, use the left and
right arrows to select the AM/PM field.
Select AM/PM field
Use the + button at the bottom of the display to set the
AM/PM field.
Press the BACK button at the bottom of the display to
Save the setting
save the settings.
Repeat Steps 2 through 11 for the DEFROST LOCK 2 time,
Select DEFROST LOCK 2
if desired.
Repeat Steps 2 through 11 for the DEFROST LOCK 3 time,
Select DEFROST LOCK 3
if desired.
- 26 -
Table 15.
Procedure
Figure 23.
© 2022, Marmon Foodservice Technologies Inc.