Brix Setup Menu - Cornelius VIPER E 2 FLAVOR Manual

Hide thumbs Also See for VIPER E 2 FLAVOR:
Table of Contents

Advertisement

Viper Installation, Service & Decommissioning Manual
cycles. Pressing the BACK button returns to the Choose menu and saves the changes. The description of each item in the Totals
list is shown in Table 50.
To move between one set of barrel parameters and the next, press the Right or Left arrow keys. This highlights the first entry of
the second barrel, etc.
Display
POWER ON
HHHHH:MM
SLEEP
HHHHH:MM
SYSTEM ERROR
HHHHH:MM
COMP RUN #1
HHHHH:MM
COMP CYCLES #1
########
BARREL REFG #1
HHHHH:MM
MOTOR ON #1
HHHHH:MM
MOTOR SEAL #1
HHHHH:MM
DEFROST #1
HHHHH:MM
FILL CYCLES #1
########
SYRUP RUN #1
HH:MM:SS
SYRUP OUT #1
HHHHH:MM
ERROR #1
HHHHH:MM

BRIX Setup Menu

BRIX is important to the quality of the final product. The BRIX menu facilitates the extraction of a sample of product from the
unit for BRIX measurement. There is an automatic three second dispense of product that produces a constant volume so that
a BRIX comparison can be made between samples. To perform a BRIX test, perform the procedure in Table 51.
Step
Action
1
Set status of barrels
Remove drip tray/Splash
2
panel
3
Set product supply valve
4
Access BRIX menu
Publication Number: 620073146SER
TOTALS
POWER ON
SLEEP
00034:21
SYSTEM ERROR 00003:45
COMP RUN
#1 00006:53
12:51P
COMP CYCLES#1 0000012
MAR 04
BARREL REFG#1 00006:54
BACK
Figure 53. Totals Screen
Table 50.
Value
Shows how long the machine has been powered up
Shows how long the machine has been in sleep mode
Shows how long the machine has had a system error
Shows how long the compressor has been running since the last reset
Shows the number of compressor cycles since the last reset
Shows how long the barrel has been in refrigeration mode
Shows how long the motor has been running on a specific barrel
Shows how long it has been since the motor seal was inserted on a specific barrel
Shows how long the barrel has been in defrost mode
Shows the number of times the barrel has filled with product
Shows how long the syrup solenoid has been open
Shows how long the syrup has been out
Shows how long the barrel has had an error
Table 51.
Make sure the status of all barrels is OFF on the control display.
For classic model remove the drip tray, loosen the two screws holding the splash panel
and remove it. (Fig. 55).
For Carbon model prior to removing drip tray, remove splash panel and drip tray cladding
and then loosen the two screws holding the splash panel and remove it.
Turn product supply valve to the 180 degree (BRIX) position for the barrel you are testing.
(See Figure 57).
Press MENU. Then press the SETUP button.
- 68 -
00079:34
Description
Procedure
© 2022, Marmon Foodservice Technologies Inc.