NOTE: Setting the wake up time ahead of the sleep time on a given day causes the unit to go into the sleep mode for a
week unless the operator initiates a manual wake up.
Step
1
2
3
4
5
6
7
8
9
10
11
When the sleep and wake up settings are complete, press the BACK button to save the settings and return to the Select menu, shown in
Figure 19.
Setting Viscosity
The viscosity maintained in the freeze barrels depends on the type of product being served. Some products are served best at a higher
viscosity, while others require a lower viscosity for best quality. The Viscosity menu allows the user to adjust the viscosity in each barrel
to the optimum setting for each type of syrup.
Refer to for Table 20. recommended settings based on syrup type.
Step
1
2
3
4
To set all barrels in the system to the same viscosity setting, follow Table 17., and then press the ALL button at the bottom of the display
while highlighting the viscosity setting you desire for all the barrels.
© 2022, Marmon Foodservice Technologies Inc.
Table 16.
Action
Set sleep and wake up
Open the Events Setup menu, shown in Figure 23.
times
by pressing the GO button.
Select DAY
Use the up and down arrows to highlight DAY.
Use the + or - buttons at the bottom of the display
Set DAY
to set the desired day or all days.
Select SLEEP
Use the up and down arrows to highlight SLEEP.
Use the left and right arrows to select the hour
Set hour field
field.
Use the left and right arrows to select the minute
Set minute field
field.
If the 12 hour clock option is selected, use the left
Select AM/PM field
and right arrows to select the AM/PM field.
Select DAY for Wake up
Repeat Steps 1 through 3.
Use the up and down arrows to highlight WAKEUP
Select WAKEUP
and repeat Steps 6 through 8 to set the WAKEUP
times.
Set Wake up day/time
Repeat Steps 5 through 7.
Save the WAKEUP set-
Press the BACK button at the bottom of the display
ting
to save the wake up setting.
Table 17.
Action
From the Setup menu (Figure 19.), open the Vis-
Set viscosity range
cosity Setup menu, shown in Figure 24..
Use the up and down arrows to highlight the
Select barrel
desired barrel.
Use the + or - buttons at the bottom of the display
Set range
to set the desired range.
Repeat Steps 2 and 3 for each barrel in the
Select barrel
machine.
- 27 -
Viper Installation, Service & Decommissioning Manual
Procedure
Procedure
Publication Number: 620073146SER