Setting The Temperature Format; Setting The Date Format; Setting The Time Format; Setting The Pos Lighting - Cornelius VIPER E 2 FLAVOR Manual

Hide thumbs Also See for VIPER E 2 FLAVOR:
Table of Contents

Advertisement

Viper Installation, Service & Decommissioning Manual
Temp Format
Date Format
Time Format
POS Lighting
#1 SYRUP TYPE
#X SYRUP TYPE
When all the options are set to the desired settings for the unit, press the BACK button to store these settings and return to the
Select menu.

Setting the Temperature Format

The temperature format displayed by the unit may be set to either Centigrade or Fahrenheit. Press the °F button to display
readings in Fahrenheit and press the °C button to display readings in Centigrade.

Setting the Date Format

The date format can be displayed in either United States or European format. To display U.S. date format, press the USA
button. This displays the date in mm/dd/yy format. Press the EURO button to display the date in dd/mm/yy format.

Setting the Time Format

Time format can be displayed in either 12 or 24 hour format. To display the clock settings in 12 hour format (1:08 P), press the
12 HR button. To display settings in 24 hour format (23:05), press the 24 HR button.

Setting the POS Lighting

POS Lighting is controlled by the POS LIGHTING field on the Option Setup menu (Figure 49). To turn off the merchandiser
lighting, press the OFF button while the POS LIGHTING field is highlighted. To turn on the merchandiser lighting permanently,
press the ALWAYS button. To turn the merchandiser lighting on and off with the Sleep settings, press the SLEEP button.

Setting the Type of Syrup

Syrup type for each barrel may be selected by highlighting the desired barrel and pressing the appropriate button, FCB, FCB-L,
FUB or FUB-L. FCB is for Frozen Carbonated Beverage, FCB-L is for Frozen Carbonated Beverages - Light (diet), FUB is for Frozen
Uncarbonated Beverages and FUB-L is for Frozen Uncarbonated Beverages - Light (diet). Each of these settings provides the
proper viscosity and temperature settings for the type of syrup being used.

Maintenance Menu

The maintenance menu, shown in Figure 51 is only available to service personnel or other authorized users, if security is
enabled.
The Maintenance menu is used for barrel maintenance, diagnostics, BRIX setup and system information. It allows the
technician access to the unit during periodic maintenance or troubleshooting problems. It sometimes overrides the normal
inputs from the system in order to perform this task.
Publication Number: 620073146SER
Option
Button 2
FCB
FCB
- 64 -
Table 44.
Button 3
Button 4
°
F
USA
12 HR
OFF
ALWAYS
FCB-L
FUB
FCB-L
FUB
Button 5
°
C
EURO
24 HR
SLEEP
FUB-L
FUB-L
© 2022, Marmon Foodservice Technologies Inc.