Concentrate Loading And Brixing; Placing Concentrate Products On Dispensing Platform; Changing Concentrate Flavor; Pump Priming - Cornelius QUANTUM SERIES Installation And Service Manual

Corneilus installation & service manual beverage dispenser quantum series
Table of Contents

Advertisement

Quantum Series Installation and Service Manual
P
C
LACING
ONCENTRATE
To engage the concentrate container, place it in the desired position and press down into bottle
adapter opening on dispensing platform tray (inside the cabinet).
NOTE: Make sure o-ring seal on the container adapter is lubricated; otherwise, you
may experience difficulties with container replacement.
NOTE: Concentrate in the containers must be completely thawed and be within the
temperature range of 35°F
the recommended temperature range, especially below 35°F (1.6°C), will cause an
out of brix drink.
It is recommended the concentrate be thawed in a refrigerated (35°F
partment for 36 to 48 hours before use.
It is recommended that the thawed concentrate be thoroughly shaken before use.
C
C
HANGING
ONCENTRATE
1. Perform flush cycle
2. Move valve handle to "Dispense" position
3. Replace concentrate container
P
P
UMP
RIMING
1. Follow instructions in paragraph "Placing Concentrate Products on the Dispensing Platform"
2. Close the door (or unit will not activate)
3. Depress the push button until concentrate appears at the dispensing nozzle.
B
S
RIX
ETTING
1. Make two (2) full clockwise turns of the corresponding brix knob from the "all the way out" po-
sition (factory set). These two turns will bring you within one turn of proper brix setting. (Refer
to brix table located on the inside of the refrigerated compartment door).
2. Dispense 1/2 cup of juice and discard.
3. Dispense 1/2 cup of juice and use refractometer to check brix level.
4. Clockwise rotation of the knob decreases brix level for example from 13% to 11.5%. Counter-
clockwise will increase brix level for example from 11.5% to 13%.
If a brix problem is experienced, refer to troubleshooting guide.
CONCENTRATE
LOADING AND BRIXING
P
D
RODUCTS ON
40°F (1.6°C - 4.4°C). Failing to supply concentrate inside
-
F
LAVOR
- 5 -
P
ISPENSING
LATFORM
40°F) (1.6°C - 4.4°C) com-
-
720901120

Advertisement

Table of Contents
loading

Table of Contents