BRIX Setup Menu

Publication Number: 621260373SER
Display
MOTOR SEAL #1
HHHHH:MM
DEFROST #1
HHHHH:MM
FILL CYCLES #1
########
SYRUP RUN #1
HH:MM:SS
SYRUP OUT #1
HHHHH:MM
ERROR #1
HHHHH:MM
BRIX is important to the quality of the final product. The BRIX menu facilitates the
extraction of a sample of product from the unit for BRIX measurement. There is an
automatic three second dispense of product that produces a constant volume so
that a BRIX comparison can be made between samples. To perform a BRIX test,
perform the procedure in Table 26.
Step
Action
1
Set status of barrels
Remove drip tray/
2
access panel
Set product supply
3
valve
4
Access BRIX menu
5
Set barrel for BRIX
6
7
Select barrel
Perform BRIX proce-
8
dure
9
10
- 40 -
Table 25
Value
Shows how long it has been since the motor
seal was inserted on a specific barrel
Shows how long the barrel has been in
defrost mode
Shows the number of times the barrel has
filled with product
Shows how long the syrup solenoid has
been open
Shows how long the syrup has been out
Shows how long the barrel has had an error
Table 26
Make sure the status of all barrels is OFF on
the control display.
Remove the drip tray, loosen the two screws
holding the access panel and remove it. (Figure
30)
Turn product supply valve to the 180 degree
(BRIX) position for the barrel you are testing.
(See Figure 31)
Press MENU. Then press the SETUP button.
From the Setup screen (Figure 19), open the
BRIX Setup screen, shown in Figure 29
Use the Up and Down arrows to highlight BRIX
SETUP. Press the GO button at the bottom of
the display.
Use the Up and Down arrows to highlight the
desired barrel for BRIXing.
Locate the appropriate barrel sample tube and
hold a cup under it.
Open the valve at the end of the sample tube.
Press the BRIX button, and wait 3-5 seconds.
The product pump pumps product for approxi-
mately 3 seconds. After the sample is dis-
pensed Press BRIX twice more to dispense
product two more times. Discard all three of
these samples.
Press the BRIX button a fourth time. Collect this
sample in a cup and close the valve at end of
the sample tube.
Description
Procedure
© 2008-2012, IMI Cornelius Inc.