A
W
DJUSTING
ATER
(see Figure 3)
NOTE: Make sure the dispensing valve water flow rate is as desired before adjusting the valve for
Water- to-Syrup ''Ratio'' (Brix) of the dispensed product.
Adjust Water–to–Syrup "Ratio" (Brix) of the dispensed product by using ratio cup (P/N 311100000) and syrup
diversion tube assembly (P/N 319540000) as follows:
1. Remove cover from the dispensing valve by lifting front cover up 1/4 inch and pulling forward.
2. Install syrup diversion tube assembly on the dispensing valve by pushing the rubber end of the syrup diversion
tube onto the syrup outlet of the inner nozzle.
Notice: Refer to syrup manufacturer's recommendations on syrup package for water-to-syrup ratio.
3. Dispense enough to fill syrup diversion tube with syrup.
4. Hold large chamber of the ratio cup under the dispensing valve nozzle. Place free end of the syrup diversion
tube into the syrup chamber marked for the proper ratio. Dispense approximately 6 ounces of water into the
ratio cup. Water and syrup levels should be even in cup.
NOTE: Adjusting screw stops are built into the valve to prevent leakage when the screws are
adjusted clockwise too much. Stop adjusting clockwise when turning resistance increases. Turn
the screw counterclockwise 1–1/2 turns after the stop are contacted.
5. Adjusting Syrup Flow Regulator – If water and syrup levels are uneven in the ratio cup, adjust by turning the
dispensing valve syrup flow regulator adjusting screw labeled SYRUP as follows.
A. For less syrup, turn the adjusting screw counterclockwise no more than 1/4 turn at a time.
B. For more syrup, turn the adjusting screw clockwise no more than 1/4 turn at a time.
6. Repeat water-to-syrup ratio test and adjust syrup flow regulator as many times as necessary until proper ratio
of dispensed drink is achieved.
7. Remove syrup diversion tube assembly from dispensing valve.
8. Install dispensing valve front cover.
C
S
LEANING AND

Daily Cleaning of Unit

1. Remove cup rest from the drip tray.
2. Wash drip tray in place on the Unit, then rinse drip tray with hot water allowing water to drain out through the
drain hose.
3. Wash cup rest, then rinse the cup rest with clean water. Install cup rest in the drip tray.
4. Clean all external surfaces of the Unit with a sponge. Rinse out the sponge with clean water, then wring excess
water out of the sponge and wipe off all external surfaces on the Unit. Wipe Unit dry with a clean soft cloth. DO
NOT USE ABRASIVE CLEANERS.
5. Remove nozzle and syrup diffusers from the dispensing valves. Place nozzles and syrup diffusers in sanitizing
solution.
6. Wash the nozzles and syrup diffusers in sanitizing solution, then rinse them with potable water.
7. Re-install nozzles and syrup diffusers back on the dispensing valves.
Publication Number: 312031005INS
-