Setting Defrost Lockout - Cornelius VIPER 2 FLAVOR Service Manual

Hide thumbs Also See for VIPER 2 FLAVOR:
Table of Contents

Advertisement

Viper Service Manual

Setting Defrost Lockout

Publication Number: 621260373SER
Step
Action
6
Set minute field
7
Select AM/PM field
Select DAY for
8
Wakeup
9
Select WAKEUP
When the sleep and wakeup settings are complete, press the BACK button to
save the settings and return to the Select menu, shown in Figure 19.
From the Barrel Status menu, shown in Figure 14, press the MENU button and
then press the SETUP button to display the Setup menu. Use the up and down
arrows on the right of the control to highlight the Events Setup menu, then press
GO to enter the menu (Figure 22).
The lockout can also be set day by day or for all days with up to three lockout
periods of three hours each per day. These lockout periods may be overlapped to
provide from three to nine hours of defrost lockout, if desired. When the periods
are overlapped, it is recommended that the defrost lockouts for sequential lockout
periods be overlapped by 15 minutes. The defrost lockout affects all barrels in the
unit. To set the defrost lockouts, perform the procedure in Table 17.
Step
Action
1
Set defrost lockout
2
Select DAY
3
Set DAY
Select DEFROST
4
LOCK 1
5
Set hour field
6
7
Set minute field
8
9
Select AM/PM field
10
Select DEFROST
11
LOCK 2
- 32 -
Table 16
Procedure
Use the left and right arrows to select the min-
ute field and press the + or - buttons to change
the minutes (15 min. increments)
If the 12 hour clock option is selected, use the
left and right arrows to select the AM/PM field.
Then press the + or - buttons to change
between AM and PM.
Repeat Steps 2 and 3 as needed.
Use the up and down arrows to highlight
WAKEUP and repeat Steps 5 through 7 to set
the WAKEUP times.
Table 17
Procedure
Open Events Setup menu, shown in Figure 22
The DAY field is highlighted.
Use the + and - buttons at the bottom of the dis-
play to set the desired day or all days.
Use the up and down arrows to highlight
DEFROST LOCK 1.
Use left and right arrows to select hour field
Use the + and - buttons at the bottom of the dis-
play to set the desired hour.
Use left and right arrows to select minute field
Use the + and - buttons at the bottom of the dis-
play to set the desired minute (in 15 min. incre-
ments).
If the 12 hour clock option is selected, use the
left and right arrows to select the AM/PM field.
Use the + button at the bottom of the display to
set the AM/PM field.
Repeat Steps 2 through 10 for the DEFROST
LOCK 2 time, if desired.
© 2008-2012, IMI Cornelius Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Viper 3 flavorViper 4 flavor