Select a location in a well ventilated area, close to a grounded electrical outlet. If possible do not place the unit close to hot
and/or steaming machines.
M
A
INIMUM
IRFLOW
The minimum airflow clearance is: 4" (10.16 cm) in back, 12" (30.48 cm) on top, 4" (10.16) at sides and open to the front.
!
IMPORTANT:
Condenser air is drawn in from the bottom of the rear panel and discharged out the top of the rear panel & side panels.
Failure to maintain clearance space will reduce capacity of the unit and cause premature compressor failure.
The Dispenser needs to be placed using 4" legs that are included.
Minimum 12'' Air Flow
Clearance at Top
© 2018, Cornelius Inc.

REQUIREMENTS

C
LEARANCE
Figure 3
- 7 -
Nitropro Mini Installation Manual
Minimum 4''
Clearance at Back
and 4'' at Sides
Publication Number: 548000106INS