31 March, 1999
1. RSS (REMOTE SERVICE SYSTEM)
1.1 RSS SET UP
[D]
Line
Adapter
Machine No.
Jumper set
PI device code
ø
CAUTION
Unplug the machine power cord before starting the following procedure.
NOTE: When connecting only one machine to the line adapter, start from step 6.
1. Remove the right cover [A] (1 screw).
2. Remove the shield cover [B] (3 screws) (A259/A260 only).
3. Set the jumper TB104 [C] on the main control board as shown (default setting
is 1-2).
4. Set the PI device code with SW101 [D] on the main control board (default 0).
5. Reinstall covers.
6. Turn on the main power switch.
7. Connect the modular cord [E] to the left modular connector, as shown.
8. Install the line adapter (refer to chapter 2-1 L-ADP Installation Procedure in the
CSS L-ADP Service Manual).
[C]
[A]
[B]
A259I303.WMF
1
2-3
0
[E]
2
3
2-3
2-3
1
2
1
RSS SET UP
A259I302.WMF
A259I304.WMF
4
5
2-3
1-2
3
4

Advertisement