10. Replace the transfer belt and reset the transfer belt bracket.
NOTE: When installing a new transfer belt, make sure that the belt rims at both
ends are past the ends of the roller.
11. Turn the transfer belt release lever in the direction shown above [A], and apply
setting powder [B] to the entire belt surface, before putting back the cleaning
unit [C].
12. Attach the cleaning unit to the transfer belt unit and turn the joint section of the
cleaning unit [D] in the direction shown above, to pressurize the blade.
13. After pressurizing the blade, rotate the belt one turn in the direction shown
above [E] to orient the belt with the blade.
NOTE: Failure to execute steps 11 to 13 may cause the belt to catch on the blade.
This will cause the LCD to display SC452 (transfer belt home position
detection error) or the blade bracket may become bent.
14. Set the belt tension release lever to the "Transfer Belt Release Position [F]"
and reinstall the transfer belt unit.
Hint for reinstalling the transfer belt unit.
When installing the transfer belt unit, hold it up with one hand underneath at the
rear and slide it in along the rails. If it is not held up, it will not engage the coupling
gears properly.