Ricoh Aficio Color 3006 Service Manual page 296

Table of Contents

Advertisement

24 February, 1999
[B]
7. Hook the spring [A] onto the wire tension bracket [B], then loosen and retighten
the screw permanently.
8. Secure the wire with the scanner wire clamp [C].
9. Remove the scanner locking pins [D].
10. Replace all the parts removed earlier, except for those removed in step 1.
11. After tensioning the wire by executing a scanner free run (SP mode 4-013-001),
reset the scanner locking pins [D]. If the pins do not properly fit into the holes,
loosen and reset the scanner wire clamp [C] so that the pins properly fit into the
holes.
12. Replace the parts removed in step 1.
[D]
[A]
6-25
SCANNER UNIT
[C]
A259R013.WMF