24 February, 1999
Item
SP No.
[Display]
05-810: [SC Reset]
05-810-00
[SC Reset]
05-811: [Serial No.]
05-811-00
05-812: Service Telephone Number [Service Tel.No.]
05-812-00
5-816: [RDS On/Off]
5-816-00
5-817: [Repair Time Tx]
5-817-00
05-824: NVRAM Upload [NVRAM Up Load]
[NVRAM Up Load]
05-824-00
05-825: NV-RAM download [NVRAM Down Loa]
05-825-00
[NVRAM Down Load]
Default
Value Range
Step
Value
0 to 1
0
0: OFF
1: ON
-
0: End
1: Start
0 to 1
0 to 1
47
SP7-
Description
902/3
Resets a type A service call condition, which is
caused by the fusing section.
1 = Reset
After resetting the SC code, the main switch has to
be turned off and on.
Displays the serial number
Inputs the telephone number of the service
representative. (This number is displayed when a
service call condition occurs.)
When the machine is connected to an RDS system,
set this SP to "1" to enable the RDS functions.
When using an RDS system, set this SP mode to 1 at
the start of maintenance. Set it back to 0 after
finishing maintenance.
Uploads data from the NV-RAM to the IC card. See
'Replacement & Adjustment – System & Electronics'.
Downloads data from the IC card to the NV-RAM.
See 'Replacement & Adjustment – System &
Electronics'.