24 February, 1999
Item
SP No.
[Display]
04-932: Main scan dot position correction [Picture Element Correction]
04-932-01
[Red: Left]
04-932-02
[Red: Right]
04-932-03
[Blue: Left]
04-932-04
[Blue: Right]
04-980: [FPU Reference setting]
04-980-01
[Red: Positive]
04-980-02
[Green: Positive]
04-980-03
[Blue: Positive]
04-980-04
[Red: Negative]
04-980-05
[Green: Negative]
04-980-06
[Blue: Negative]
04-981: [FPU White level Target]
04-981-01
[Positive]
04-981-02
[Negative]
Default
Value Range
Step
Value
5
0 to 9
1
5
0 to 9
1
5
0 to 9
1
5
0 to 9
1
133
0 to 255
1
133
0 to 255
1
133
0 to 255
1
133
0 to 255
1
133
0 to 255
1
133
0 to 255
1
568
0 to 1023
1
568
0 to 1023
1
41
SP7-
Description
902/3
Adjusts the left and right ends of the red and blue
scan lines to align them with the green scan line.
See 'Replacement and Adjustment – Copy Image
Adjustment – Main Scan Position Dot Correction' for
how to use these SP modes.
Adjusts or displays the reference value used in the
A/D converter for RGB signals in the scanner analog
processing circuit when the FPU is used.
There is no need to use these SP modes with the
FPU that is specified for use with the Iris/Lilac.
Shows or sets the target level of the reference white
level for positive and negative film when the FPU is
used.
There is no need to use these SP modes with the
FPU that is specified for use with the Iris/Lilac.
SP TABLE