Ricoh Aficio Color 3006 Service Manual page 371

Table of Contents

Advertisement

SP TABLE
Item
SP No.
[Display]
1-101: Oil End Sensor [Oil End Sensor]
1-101-000
[Fuser Oil End Check]
01-104:
01-104-00
Fusing control method selection
[Fusing Control]
01-105: Hot/pressure roller temperature settings [Roller.Tmp Set]
01-105-01
Hot roller, 1st side, Idling
[Hot Rllr/ Idling]
Default
Value Range
Step
Value
1
0 = Not used
1
1 = Used
1
0: Phase control
1
1: On/off control
163 °C
100 to 200 °C
1
2
SP7-
Description
902/3
Yes
Specifies whether the oil end sensor is used.
Yes
Selects the fusing temperature control mode.
On/off control minimizes the radio noise generated
when the fusing lamp is turned on.
Phase control should only be selected if a user has
problems with electrical noise or interference, such
as a flickering fluorescent lamp or main power supply
voltage drops.
The main switch needs to be turned off and on when
the setting is changed.
0 = Phase control
1 = ON/OFF control.
Yes
Sets the temperature at which idling starts.
Idling starts for 2 minutes when the temperature
becomes over the target - 15 °C.
If the temperature is higher than 50 °C when the
power relay turns on, idling is not executed.
24 February, 1999