24 February, 1999
DRUM UNIT
NOTE: 1) After replacing the drum or the cleaning blade, rotate the drum
forward two or three times to settle the setting powder between the
drum surface and the cleaning blade.
2) When installing the cleaning blade [A], make sure that the front and
rear ends of the blade do not rest over the cleaning unit side seal
[B].
[NG]
[OK]
[A]
[B]
A259R217.WMF