Syslog Messages - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Tag
Description
{Subject}
String (with space) for the subject in the
certificate. Used as part of the certificate-based
authentication and must include Unicode
characters.
{Config
String (with space) for the configuration
detail}
{Connection
Name of the VPN connection
name}
{Firewall
Firewall action executed (accepted package)
accept}
{Firewall
Firewall action executed (rejected package)
action
reject}
{Length}
Length of the network packet (in bytes)
{Network
Symbolic name of a network interface
interface}
A.3

Syslog messages

This section describes the Syslog messages. The structure of the messages is based on
IEC 62443-3-3.
Note
Severity
Some severities are grouped in the firmware:
• Info + Notice = Info
• Warning + Error = Warning
• Critical + Emergency = Critical
Identification and authentication of human users
Message text
Example
Explanation
Severity
Facility
Standard
Message text
Example
Explanation
Severity
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
{protocol}: User {User name} has logged in from {ip address}.
WBM: User "Admin" has logged in from 192.168.0.1.
Valid login information that is specified during remote login.
Info
local0
IEC 62443-3-3 Reference: SR 1.1
{protocol}: User {User name} failed to log in from {ip address}.
WBM: User "Admin" has failed to log in from 192.168.0.1.
Incorrect user name or incorrect password (login information) specified
during remote login.
Error
Format
Possible values or
example
%s
(Peter Maier)
With UTF8 code: %S
%s
OpenVPN
to_Baugruppe1
ACCEPT
REJECT DROP
%d
52
%s
vlan 1
Appendix A
A.3 Syslog messages
359